SERIES 571
Features
- ABSOLUTE Digimatic Depth Gage can keep track of the origin point once set for the entire life of the
- Base and measuring faces are hardened and micro-lapped.
- Optional wider extension bases are (up to 450mm range models)
- With SPC data output.
Specifications
Metric
Range | Order No. | Resolution | Accuracy | Mass(g) |
0 – 150mm | 571-201-20 | 0.01mm | ±0.02mm | 192 |
0 – 150mm | 571-251-10* | 0.01mm | ±0.02mm | 199 |
0 – 200mm | 571-202-20 | 0.01mm | ±0.02mm | 212 |
0 – 200mm | 571-252-10* | 0.01mm | ±0.02mm | 219 |
0 – 300mm | 571-203-20 | 0.01mm | ±0.03mm | 310 |
0 – 300mm | 571-253-10* | 0.01mm | ±0.03mm | 320 |
0 – 450mm | 571-204-10 | 0.01mm | ±0.05mm | 1270 |
0 – 600mm | 571-205-10 | 0.01mm | ±0.05mm | 1400 |
0 – 750mm | 571-206-10 | 0.01mm | ±0.06mm | 1530 |
0 – 1000mm | 571-207-10 | 0.01mm | ±0.07mm | 1760 |
Inch
Range | Order No. | Resolution | Accuracy | Mass(g) |
0 – 6” /
0 – 150mm |
571-211-20 | .0005” /
0.01mm |
±.001” | 192 |
0 – 6” /
0 – 150mm |
571-261-10* | .0005” /
0.01mm |
±.001” | 199 |
0 – 8” /
0 – 200mm |
571-212-20 | .0005” /
0.01mm |
±.001” | 212 |
0 – 8” /
0 – 200mm |
571-262-10* | .0005” /
0.01mm |
±.001” | 219 |
0 – 12” /
0 – 300mm |
571-213-10 | .0005” /
0.01mm |
±.0015” | 310 |
0 – 12” /
0 – 300mm |
571-263-10* | .0005” /
0.01mm |
±.0015” | 320 |
0 – 18” /
0 – 450mm |
571-214-10 | .0005” /
0.01mm |
±.002” | 1270 |
0 – 24” /
0 – 600mm |
571-215-10 | .0005” /
0.01mm |
±.002” | 1400 |
0 – 30” /
0 – 750mm |
571-216-10 | .0005” /
0.01mm |
±.0025 | 1530 |
0 – 40” /
0 – 1000mm |
571-217-10 | .0005” /
0.01mm |
±.0025 | 1760 |
Dimensions
Technical Data
- Resolution: .0005”/0.01mm or 0.01mm Repeatability:0.01mm
- Display: LCD
- Length standard: ABSOLUTE electrostatic capacitance (electromagnetic induction)* type linear encoder
- Max. response speed: Unlimited Battery: SR44 (1 pc.), 938882
- Battery life: Approx. 20,000 hours (3 years)* under normal use Dust/Water protection level: IP67*
- *Coolant Proof models
Function
- Origin-set, Zero-setting, Automatic power on/off, Data output, inch/mm conversion (on inch/metric models only) Alarm: Low voltage, Counting value composition error